3D Workspace
Home
Assets
Affiliate Program
Sign up/Log in
?
Upgrade
DCC Bridge
3D Creation Made Simple
Text & Image to 3D Model in seconds
One-Click Texturing & Smart Detail Editing
Free Credits Monthly
Start Free
Anonymous1772785879
03-06 08:41
Model Name
solid-state bioreactor 3d model
Tags
machine
rendering
realistic
Prompt
Solid-State Bioreactor Design Specifications 1. Main Reactor (External Dimensions) • Length: 30 cm • Breadth: 10 cm • Height: 15 cm • Wall Thickness: 2.5 cm ⸻ 2. Main Reactor (Internal Dimensions) • Internal Length: 27.5 cm • Internal Breadth: 7.5 cm • Internal Height: 12.5 cm ⸻ 3. Substrate Tray System The reactor contains perforated substrate trays supported by side brackets to keep them elevated and allow airflow underneath. Tray Dimensions • Tray Length: 25 cm • Tray Width: 7 cm Tray Arrangement • Two trays are installed inside the reactor. • The bottom tray is positioned 2 cm above the base of the reactor. • The distance between the two trays is 5 cm. • The top tray is positioned approximately 4.5 cm below the top section of the reactor. Function • The perforated trays allow airflow below the substrate, which supports oxygen availability during solid-state fungal growth. ⸻ 4. Water / Nutrient Distribution System A top-mounted water pipe distributes moisture or nutrients over the substrate. Pipe Specifications • Pipe Length: 28 cm • Pipe Diameter: 2 cm • The pipe should include threads for attaching sprinkler nozzles. Sprinkler System • Three sprinkler nozzles are attached to the pipe. • The sprinklers should be equally spaced (~6 cm apart). Spacing • Maintain a 3.5 cm gap from both inner side walls of the reactor. • The distance between each sprinkler should be approximately 6 cm. This ensures uniform moisture distribution across the substrate trays. ⸻ 5. Aeration System • There is no aeration pipe inside the reactor. • Oxygen is supplied through a single aeration inlet. Airflow Design • Air Inlet Diameter: 2 cm • Air Outlet Diameter: 2 cm • Air Inlet Location: Top of the reactor • Air Outlet Location: Bottom right side of the reactor This configuration allows oxygen entry and gas exchange necessary for fungal growth. ⸻ 6. Access System • A front access door or window should be included. • The door should be placed on the front face (30 cm length side) of the reactor. • This opening allows easy loading and removal of the substrate trays and materials. ⸻
Detailed Info
Related Models
Enter invite code
Enter invite code to get credits!